Base Type G13
Beam Angle 160 Degrees
Shape T8
Compatibility Type A+B - Universal / Ballast Bypass/Compatible
CRI 83
Life Hours 50,000 Hours
Light Source LED
Lumens per Watt 130 lm/W
Lumens Range 1,500 - 3,000 Lumens
Operating Temp - Low -20C / -4F
Operation Single and Double Ended
Operating Temp - High 45C / 113F
Watt Equivalent 32 Watt
Voltage AC120-277V
Warranty 5 Year
Color 4000K Bright White
Color 5000K Daylight
Approvals and Listings DLC Listed
Approvals and Listings FCC Compliant
Approvals and Listings UL Listed
Approvals and Listings NSF
Approvals and Listings ROHS
Features Hybrid
Features Instant On
Features Long Life Span
Features Mercury Free
Features Shatter Resistant
Features Warranty
Features Glass Housing
Features Double Ended Power
Features Damp Rated
Recommended Uses dlc_listed.png
Recommended Uses fcc_compliant.png
Recommended Uses nsf.png
Recommended Uses ul_listed.png
Left Overlay Image 10 Pack.png
Lumens 1950
Brand Euri Lighting

‎
  • Details

    A smart energy-saving alternative to traditional fluorescent lighting, the Euri Lighting EUB-15W outputs high lumens for low watts. With hybrid technology, this U-Shaped LED tube makes for uncomplicated installation with or without a ballast. Shatterproof glass and built to last 50,000 hours, Euri Lighting’s EUB-15W reduces energy and maintenance worries with every use.

    Hybrid technology reduces maintenance expenses and allows adaptable installation methods whether a ballast is present or not.

    Specifications:

    • Type A+B
    • 6in. Length
    • 15W
    • 32W Fluorescent Tube Equivalent
    • 1950 Lumens
    • 83 CRI
    • Dimmable
      • Dimming requires use of dimming driver EED-100WD (sold separately)
    • Single & Double Ended Power
    • Available in 4000K and 5000K Color Temperatures
    • 160° Beam Angle
    • AC120-277V Input Voltage
    • Shatterproof Glass
    • $1.80 Estimated Yearly Cost
    • FCC, NSF, RoHs, UL Listed, DLC Listed
      • DLC Standard 5.1 Product ID - 4K: PTO2FS2D | 5K: PTLRDMMS

    Product Dimension (of one LED Linear Tube) - 22.44" L x 7" W x 1.1"H

    Discover the Benefits of Plug and Play LED Tubes

    Plug and Play LED Tubes are here to stay! They make it easy to replace fluorescent tubes and upgrade your space with bright LED light. Plug and play tubes are easy to install. The process is easy as Step 1, 2, and 3.*

    1. Turn off power to the light being changed before installation using the switch on the breaker panel.
    2. Remove the fluorescent tubes. Remember - Fluorescent tubes contain mercury and should be disposed of properly.
    3. Install the LED tubes and turn the power back on.

    *Please make sure to read the instruction manual of the LED tubes and fixture the tubes are being installed into as the above instructions may not be 100% correct per the specific tubes or product.

    Can you put led tube lights in a fluorescent fixture? Can I replace my fluorescent T8 linear bulbs with LEDs?

    Yes! LED Tubes can be installed into a fluorescent fixture. When tubes are Type A + B. Type A or Type B, it is easy to replace those flickering fluorescents. A brief explanation of Type A and B LED linear tubes is below.

    Type A LED Linear Tubes are often called "plug and play" tubes. This is because they can simply be installed into the existing fixture.

    Type B LED Linear Tubes are often referred to as "ballast bypass." They work with all fluorescent fixtures including ballast-free fixtures. Type B linear tubes power goes directly to the lamp sockets and no longer through the ballast.

    Type A + B can be used with or without a ballast. It is ultimately the buyer's preference what they want to do. Type A installation uses the LED Tube + Ballast power for more energy consumption compared to Type B installation only uses the raw tube power and is more energy-efficient.

    What does ballast bypass mean? How does ballast bypass work?

    Ballast bypass means when installing the LED linear tube, the fixture's ballast will need to be removed first. The power will then go directly to the lamp sockets and no longer through the ballast. The benefits of ballast bypass LED replacement tubes include lights not being shut down by a ballast failure, no more ballast replacements, and savings on the energy bill because energy is no longer drawing from the ballast.

    Emergency Drivers: Constant-power emergency drivers with 90-minute run time are available to add on to your LED high bays to increase fire safety and comply with local fire safety codes. Check out our selection of LED emergency drivers.

    This LED tube is DLC Standard 5.1 rated and may be eligible for additional utility rebates in certain areas. Check out our Rebate Assistant tool to find if this product qualifies for you!

    Want to learn more about getting our products at wholesale discounts? Buy LightUp LED Products in Bulk by completing the form on our wholesale page.

    Check out all that LightUp has to offer on weekly specials, new products, categories and more on our home page!

    Ballast Compatibility List

    ACT: ACT3P32ISUNVE / ATC4P32ISUNVE

    DAMAR: 1688B / 1688D / 3654C

    EIKO: PM-2X32T8-UNV-IS

    ESPEN: VE232MVHIPLE / VE2P32MVHIPE 11068 / VE2P32MVHIPHE 11069 / VE332MVHIPLE / VE3P32MVHIPE 11070 / VE3P32MVHIPLE 11056 / VE4P32MVHIPE 11072 / VE4P32MVHIPLE 11057 / VEL-4P32-SC / VEL100BN-4C / VEL30BN-2C-10V / VEL30BN-2C-10V( White) / VEL50BN-2C / REZ-2S32-SC / REZ-3S32-SC / VE2P32MVHPPE 11080 / VE4P32MVHPPE 11086

    GE: GE132MAX-G-N / GE132MAX-H/Ultra / GE-132-MV-N / GE232-120RES-B / GE232MAX-G-N / GE232MAX-G-N-DIYB / GE232MAXG-N-DIYL / GE232MAX-L/ULTRA / GE-232-MV-N / GE332MAX-G-H / GE332MAX-G-N / GE332MAX-G-N-DIYB / GE332MAXP-N/ULTRA / GE432MAX-G-N / GE432MAXG-N-DIYL / GE432MAX-L/Ultra / GE432MAX-N/Ultra / GE432MAXP-L/ULTRA / GE132-MVPS-H / GE-132-MV-PS-L / GE232-MV-PS-H / GE232-MVPS-L / GE232-MVPS-N / GE-232-MV-PS-N / GE-232-MVPS-XL GE240RES120-4PK / GE240RES120-B / GE332-MVPS-L / GE-332-MVPS-XL

    HALCO: EP2/32IS/MV/MC/HE / EP232IS/MV/HE / EP332IS/L/MV/HE / EP332IS/MV/HE / EP4/32IS/MV/MC/HE / EP432IS/L/MV/HE / EPL2/32IS/MV/MC/HE / EPL3/32IS/MV/SC/HE / EPL4/32IS/MV/MC/HE

    KEYSTONE: KTEB-232RIS-1-TP-SL/J / KTEB-232-UV-IS-N-P / KTEB-332-UV-IS-N-P / KTEB-432RIS-1-TP-SL / KTEB-432-UV-IS-N-P

    OSRAM SYLVANIA: QHE 3X32T8/UNV HT-SC / QHE 3XLEDT8/UNV-ISN-SC / QHE 4X32T8/UNV ISN-SC / QHE 4XLEDT8/UNV-ISN-SC / QHE 1X32T8/UNV ISL-SC /QHE 1X32T8/UNV ISN-SC /QHE 2X32T8/UNV ISL-SC-1 / QTP 2X59T8/UNV ISN-SC / QTP 3X32T8/UNV ISN-SC / QTP 4X32T8/UNV ISN-S / QHE 3X32T8/UNV-PSN-SC / QHE 4X32T8/UNV PSX-SC / QHE 2X32T8/UNV PSN-MC / QHE 2X32T8/UNV PSX-MC / QTP 2X32T8/UNV ISN-SC

    PHILIPS ADVANCE: ICN-1P32-N / ICN-2P32-N / ICN-3P32-N / ICN-4P32-N / IOP-2P32-HL-N / IOP-2P32-LW-N / IOP-2P32-N / IOP-2P59-N / IOPA-1P32-LW-N / IOPA-2P32-LW-N

    NOTE: Ballast compatibility testing is performed under a controlled laboratory environment.
    Installation conditions may differ from this controlled environment due to ballast age or possible ballast malfunction.

    Ballasts may have also undergone manufacturer’s revisions while retaining the same model number, which could affect compatibility.

    Before a major relamping, Euri Lighting recommends testing a sample of ballast-lamp combinations on-site to ensure compatibility.

    Only the ballasts listed on Euri Lighting’s official ballast compatibility list have been tested and verified as compatible.

    Euri Lighting is not liable for any installations that utilize ballasts not listed.

  • Warranty Information

A smart energy-saving alternative to traditional fluorescent lighting, the Euri Lighting EUB-15W outputs high lumens for low watts. With hybrid technology, this U-Shaped LED tube makes for uncomplicated installation with or without a ballast. Shatterproof glass and built to last 50,000 hours, Euri Lighting’s EUB-15W reduces energy and maintenance worries with every use.

Hybrid technology reduces maintenance expenses and allows adaptable installation methods whether a ballast is present or not.

Specifications:

  • Type A+B
  • 6in. Length
  • 15W
  • 32W Fluorescent Tube Equivalent
  • 1950 Lumens
  • 83 CRI
  • Dimmable
    • Dimming requires use of dimming driver EED-100WD (sold separately)
  • Single & Double Ended Power
  • Available in 4000K and 5000K Color Temperatures
  • 160° Beam Angle
  • AC120-277V Input Voltage
  • Shatterproof Glass
  • $1.80 Estimated Yearly Cost
  • FCC, NSF, RoHs, UL Listed, DLC Listed
    • DLC Standard 5.1 Product ID - 4K: PTO2FS2D | 5K: PTLRDMMS

Product Dimension (of one LED Linear Tube) - 22.44" L x 7" W x 1.1"H

Discover the Benefits of Plug and Play LED Tubes

Plug and Play LED Tubes are here to stay! They make it easy to replace fluorescent tubes and upgrade your space with bright LED light. Plug and play tubes are easy to install. The process is easy as Step 1, 2, and 3.*

  1. Turn off power to the light being changed before installation using the switch on the breaker panel.
  2. Remove the fluorescent tubes. Remember - Fluorescent tubes contain mercury and should be disposed of properly.
  3. Install the LED tubes and turn the power back on.

*Please make sure to read the instruction manual of the LED tubes and fixture the tubes are being installed into as the above instructions may not be 100% correct per the specific tubes or product.

Can you put led tube lights in a fluorescent fixture? Can I replace my fluorescent T8 linear bulbs with LEDs?

Yes! LED Tubes can be installed into a fluorescent fixture. When tubes are Type A + B. Type A or Type B, it is easy to replace those flickering fluorescents. A brief explanation of Type A and B LED linear tubes is below.

Type A LED Linear Tubes are often called "plug and play" tubes. This is because they can simply be installed into the existing fixture.

Type B LED Linear Tubes are often referred to as "ballast bypass." They work with all fluorescent fixtures including ballast-free fixtures. Type B linear tubes power goes directly to the lamp sockets and no longer through the ballast.

Type A + B can be used with or without a ballast. It is ultimately the buyer's preference what they want to do. Type A installation uses the LED Tube + Ballast power for more energy consumption compared to Type B installation only uses the raw tube power and is more energy-efficient.

What does ballast bypass mean? How does ballast bypass work?

Ballast bypass means when installing the LED linear tube, the fixture's ballast will need to be removed first. The power will then go directly to the lamp sockets and no longer through the ballast. The benefits of ballast bypass LED replacement tubes include lights not being shut down by a ballast failure, no more ballast replacements, and savings on the energy bill because energy is no longer drawing from the ballast.

Emergency Drivers: Constant-power emergency drivers with 90-minute run time are available to add on to your LED high bays to increase fire safety and comply with local fire safety codes. Check out our selection of LED emergency drivers.

This LED tube is DLC Standard 5.1 rated and may be eligible for additional utility rebates in certain areas. Check out our Rebate Assistant tool to find if this product qualifies for you!

Want to learn more about getting our products at wholesale discounts? Buy LightUp LED Products in Bulk by completing the form on our wholesale page.

Check out all that LightUp has to offer on weekly specials, new products, categories and more on our home page!

Ballast Compatibility List

ACT: ACT3P32ISUNVE / ATC4P32ISUNVE

DAMAR: 1688B / 1688D / 3654C

EIKO: PM-2X32T8-UNV-IS

ESPEN: VE232MVHIPLE / VE2P32MVHIPE 11068 / VE2P32MVHIPHE 11069 / VE332MVHIPLE / VE3P32MVHIPE 11070 / VE3P32MVHIPLE 11056 / VE4P32MVHIPE 11072 / VE4P32MVHIPLE 11057 / VEL-4P32-SC / VEL100BN-4C / VEL30BN-2C-10V / VEL30BN-2C-10V( White) / VEL50BN-2C / REZ-2S32-SC / REZ-3S32-SC / VE2P32MVHPPE 11080 / VE4P32MVHPPE 11086

GE: GE132MAX-G-N / GE132MAX-H/Ultra / GE-132-MV-N / GE232-120RES-B / GE232MAX-G-N / GE232MAX-G-N-DIYB / GE232MAXG-N-DIYL / GE232MAX-L/ULTRA / GE-232-MV-N / GE332MAX-G-H / GE332MAX-G-N / GE332MAX-G-N-DIYB / GE332MAXP-N/ULTRA / GE432MAX-G-N / GE432MAXG-N-DIYL / GE432MAX-L/Ultra / GE432MAX-N/Ultra / GE432MAXP-L/ULTRA / GE132-MVPS-H / GE-132-MV-PS-L / GE232-MV-PS-H / GE232-MVPS-L / GE232-MVPS-N / GE-232-MV-PS-N / GE-232-MVPS-XL GE240RES120-4PK / GE240RES120-B / GE332-MVPS-L / GE-332-MVPS-XL

HALCO: EP2/32IS/MV/MC/HE / EP232IS/MV/HE / EP332IS/L/MV/HE / EP332IS/MV/HE / EP4/32IS/MV/MC/HE / EP432IS/L/MV/HE / EPL2/32IS/MV/MC/HE / EPL3/32IS/MV/SC/HE / EPL4/32IS/MV/MC/HE

KEYSTONE: KTEB-232RIS-1-TP-SL/J / KTEB-232-UV-IS-N-P / KTEB-332-UV-IS-N-P / KTEB-432RIS-1-TP-SL / KTEB-432-UV-IS-N-P

OSRAM SYLVANIA: QHE 3X32T8/UNV HT-SC / QHE 3XLEDT8/UNV-ISN-SC / QHE 4X32T8/UNV ISN-SC / QHE 4XLEDT8/UNV-ISN-SC / QHE 1X32T8/UNV ISL-SC /QHE 1X32T8/UNV ISN-SC /QHE 2X32T8/UNV ISL-SC-1 / QTP 2X59T8/UNV ISN-SC / QTP 3X32T8/UNV ISN-SC / QTP 4X32T8/UNV ISN-S / QHE 3X32T8/UNV-PSN-SC / QHE 4X32T8/UNV PSX-SC / QHE 2X32T8/UNV PSN-MC / QHE 2X32T8/UNV PSX-MC / QTP 2X32T8/UNV ISN-SC

PHILIPS ADVANCE: ICN-1P32-N / ICN-2P32-N / ICN-3P32-N / ICN-4P32-N / IOP-2P32-HL-N / IOP-2P32-LW-N / IOP-2P32-N / IOP-2P59-N / IOPA-1P32-LW-N / IOPA-2P32-LW-N

NOTE: Ballast compatibility testing is performed under a controlled laboratory environment.
Installation conditions may differ from this controlled environment due to ballast age or possible ballast malfunction.

Ballasts may have also undergone manufacturer’s revisions while retaining the same model number, which could affect compatibility.

Before a major relamping, Euri Lighting recommends testing a sample of ballast-lamp combinations on-site to ensure compatibility.

Only the ballasts listed on Euri Lighting’s official ballast compatibility list have been tested and verified as compatible.

Euri Lighting is not liable for any installations that utilize ballasts not listed.


‎

Footer Image: Free Shipping - On Orders of $99 or more. Limited Time Offer, some restrictions may apply
Discounts & Coupons. Get these coupon codes before they expire!
Wholesale LED Lights - Buy LED Products in Bulk - click to learn more